Chapter 14 SCXI Hardware
©
National Instruments Corporation 14-7 DAQ Hardware Overview Guide
multiplex their input channels and send them on the analog bus on the
SCXI backplane. So, if you configure the SCXI-1200 for multiplexed
mode, you can use it to read the multiplexed output from other SCXI analog
input modules in the chassis. In addition, you can multiplex the analog
input channels on the SCXI-1200 with the input channels from other analog
input modules in the chassis during the same scanning operation. The
SCXI-1200 switches its analog input channels in descending order (the
other analog input modules switch their channels in ascending order). The
SCXI Application Tips section in Chapter 3, Software Overview, of the
NI-DAQ User Manual for PC Compatibles explains how to use the SCXI
functions in analog input applications with the SCXI-1200 in multiplexed
mode.
If you are not using other analog input modules in the chassis along with
the SCXI-1200, you should configure the SCXI-1200 for stand-alone
mode. In stand-alone mode you do not need the SCXI functions to perform
analog input operations, you simply use the SCXI-1200 with the
DAQ and
Lab_ISCAN functions as if it were a plug-in device inside your PC. You can
still use digital or relay modules or analog output modules in the chassis
with the SCXI-1200 configured for parallel mode; you need SCXI
functions to operate those modules.
When you perform analog input data acquisition with the SCXI-1200
connected to the parallel port of the PC, the module issues an interrupt
through the parallel port, which the PC services to retrieve data. When the
SCXI-1200 is connected to the PC through a remote SCXI configuration,
NI-DAQ will query the remote SCXI unit for the presence of acquired data,
and the remote SCXI unit will send data back serially to the PC.
SCXI Analog Input Modules
The following modules are the SCXI analog input modules.
SCXI-1100
The SCXI-1100 module has 32 differential analog input channels.
The input voltage range is 10 to +10 V. The SCXI-1100 has a
software-selectable module gain with values of 1, 2, 5, 10, 20, 50, 100, 200,
500, 1,000, and 2,000. The gain applies to all channels on the module; use
the
SCXI_Set_Gain function to select the module gain. The gain fields in
Measurement & Automation Explorer are not used by NI-DAQ; those
fields are used only by LabVIEW.
The SCXI-1100 also has a
software-selectable Calibration mode that you can use to determine the
zero offset of the module—see the
SCXI_Calibrate_Setup function
description.